China New Air -5℃ to -40℃ Low Temperature Air-Cooled Unit (24/7 Operation) - China Supplier China New Air -5℃ to -40℃ Low Temperature Air-Cooled Unit (24/7 Operation) - China Supplier China New Air -5℃ to -40℃ Low Temperature Air-Cooled Unit (24/7 Operation) - China Supplier China New Air -5℃ to -40℃ Low Temperature Air-Cooled Unit (24/7 Operation) - China Supplier China New Air -5℃ to -40℃ Low Temperature Air-Cooled Unit (24/7 Operation) - China Supplier

New Air -5℃ to -40℃ Low Temperature Air-Cooled Unit (24/7 Operation)

Price:Negotiable
Industry Category: Machinery & Industrial Equipment
Product Category:
Brand: Ninewells
Spec: JRA-20AL


Contact Info
  • Add:深圳市龙岗区坪地街道年丰社区横岭中路1号第七栋, Zip: 518116
  • Contact: 李大红先生
  • Tel:0755-29084657
  • Email:szkawai@yeah.net

Other Products

Description
Additional Information

Low-Temperature Air-Cooled Units for Scientific Research

Low-temperature air-cooled units for scientific research are air-cooled refrigeration equipment designed to provide cold sources ranging from -5°C to -40°C for research experiments. At specific temperatures, researchers can read physical data from experiments. The temperature range of the low-temperature air-cooled units introduced by our company is as follows: the new natural air can reach a low temperature of -40°C, operating continuously 24 hours a day; the cold air can reach a low temperature of -90°C, operating continuously 24 hours a day.

Working Principle

According to the principle of the refrigeration system: low-temperature, low-pressure liquid refrigerant undergoes heat exchange with the air flowing into the evaporator. The evaporator absorbs heat from the air, and during the evaporation process, the refrigerant temperature remains unchanged. The liquid refrigerant evaporates into a low-temperature, low-pressure gaseous refrigerant and enters the compressor. After being compressed by the compressor, it becomes a high-temperature, high-pressure gaseous refrigerant and then enters the condenser. In the condenser, it undergoes heat exchange with the natural air drawn in by the cooling fan, discharging the heat of the high-temperature, high-pressure refrigerant out of the unit. The refrigerant then flows out of the condenser through a dryer filter, which removes moisture or other impurities from the refrigerant during the evaporation process. It then enters the expansion valve for expansion and throttling, a process that rapidly lowers the temperature, turning the refrigerant into a low-temperature, low-pressure liquid. The refrigerant after this process re-enters the evaporator for heat exchange and evaporation, thereby completing the entire refrigeration system cycle. This cycle continues continuously, allowing for sustained refrigeration. The cold air is then delivered to the desired cooling destination through the fan via the air outlet.

Unit Selection

Low-temperature air-cooled units for scientific research are available in split and integrated designs. The split type is suitable for space cooling, with an installation method similar to that of household air conditioners: the condenser is installed outdoors, while the main unit is installed indoors. The integrated unit has a wider range of applications, with the main unit for space cooling placed outdoors and connected to air ducts leading indoors. Note: This can be designed for fresh air or recirculated air.

Unit Features:

1PLC control system.

2. Touch screen human-machine interface.

3. R485 communication port for connecting to an upper computer to read and print experimental data.

4. Temperature control: new natural air -40 to 50°C ±2; cold air -90 to 0°C ±0.5.

After-Sales Service

All equipment from our company comes with a one-year warranty and lifelong maintenance (excluding human factors and wear parts).

Upon receiving a written equipment repair notice from the customer, we respond within 36 hours for on-site repairs within Guangdong Province, and within 72 hours for on-site repairs outside Guangdong Province..

Unit Technical Parameters

19552

23.2

3×2

8

1600

8000

1.1

150

130×65×160

240

24940

29

7.5

10

2000

10000

1.5

150

148×70×168

310

29928

34.8

4.5×2

12

2400

12000

1.5

180

150×70×173

430

37410

43.5

5.5×2

15

3000

15000

2.2

180

160×75×190

480

49880

58

7.5×2

20

4000

20000

3

200

170×90×210

660

59856

69.6

9×2

25

5000

25000

3.75

200

190×100×210

740

74820

87

7.5×3

30

6000

30000

4

200

220×100×210

810

99760

116

7.5×4

40

8000

40000

5.5

200

240×140×220

980

124700

145

7.5×5

50

10000

50000

7.5

200

250×150×220

1200

Model
Model

Refrigeration Capacity
Refrigerating capacity

Compressor
Compressor

Evaporator
Evaporator

Condenser
Condenser

Fan
water pump

Air Outlet

Air outlet

Dimensions

Shape dimension

Net Weight

Net weight

kcal/h

kw

kw

hp

m3/h

m3/h

kw

mm

cm

kg

JRA-05AL

12470

14.5

3.75

5

1000

5000

0.75

125

120×60×143

160

JRA-06AL

14964

17.4

4.5

6

1200

6000

1.1

125

126×65×155

220

JRA-08AL

JRA-10AL

JRA-12AL

JRA-15AL

JRA-20AL

JRA-25AL

JRA-30AL

JRA-40AL

JRA-50AL

Industry Category Machinery & Industrial Equipment
Product Category
Brand: Ninewells
Spec: JRA-20AL
Stock: 0
Origin: China / Guangdong / Shenshi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192